46 Model E1070 Indicator User Instructions
Menu Mode
INPUT
(Input test)
18. Press the UNITS key…
INPUT is displayed. This is the input test item.
19. Press the PRINT key to access the test.
1 2 3 is displayed. 1 stands for input 1, etc.
20. If you jumper pins 1 and 2 of the I/O connector on the bottom of the
indicator…
1 becomes 0 until the jumper is removed.
To test input 2, jumper pins 1 and 3. 2 becomes 0 until the jumper
is removed.
To test input 3, jumper pins 1 and 4. 3 becomes 0 until the jumper
is removed.
21. Press the SELECT key…
INPUT is displayed.
OUTPUT
(Output test)
22. Press the UNITS key…
OUTPUT is displayed. This is the output test item.
23. Press the PRINT key to access the test.
OUT 1 is displayed. This stands for output 1.
24. Press the PRINT key…
The display toggles between ON and OFF. This will toggle the
output off and on. Monitor the output to see that it is turning off and
on. Use a Trips Interface Unit (TIU3) or other output device.
25. Stop the test by pressing the SELECT key…
OUT 1 is displayed.
26. Press the UNITS key…
OUT 2 is displayed.
27. Repeat steps 23 and 25 for outputs 2 and 3…
28. Press the SELECT key…
OUTPUT is displayed.
OPTION 29. Press the UNITS key…
OPTION is displayed.
A-OUT test 30. Press the PRINT key…
A-OUT is displayed. This stands for the analog output test.
31. Press the PRINT
key…
A numeric entry screen is displayed.
32. Key in a percentage between 0 and 100 and press the ENTER key
The analog output will put out that percentage of voltage. For
example: If you have output set from 0 to 10V and you key in a
percentage of 25, the analog output voltage should read 2.5 volts.
You can continue to key in other percentages, press ENTER and
check the analog output voltage.
33. When you are finished testing the analog output, press the ESC key…
A-OUT is displayed.

Other manuals for Avery Weigh-Tronix evolution Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Avery Weigh-Tronix evolution Series and is the answer not in the manual?

Avery Weigh-Tronix evolution Series Specifications

General IconGeneral
BrandAvery Weigh-Tronix
Modelevolution Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals