85
Model E1070 Indicator Service Manual
HOUR
(Set time)
1. From previous step 6, press the UNITS key. . .
HOUR is displayed. Set the time in this item.
2. Press the PRINT key. . .
TYPE0 is displayed. Time can be in 24 hour or 12 hour styles:
0=HH:MM
1=HH:MM AM/PM
3. Scroll through the choices using the TARE or UNITS key and press the
ENTER key when your choice is displayed. . .
HH XX is displayed. This stands for hour and its current value.
4. Key in the hour based on the type of time you selected in step 4 and
press the ENTER key. If you picked 0 (military time) in step 2, skip to
step 7. If you picked 1 (AM/PM time) continue below. . .
P? yes or P? no is displayed. P? yes for PM. P? no for AM.
5. Toggle between the choices using the TARE or UNITS key and press
the ENTER key when your choice is displayed. . .
M XX is displayed. M stands for minute and XX represents the
current value.
6. Key in the minute and press the ENTER key . . .
HOUR is displayed.
1. From previous step 6, press the UNITS key. . .
SETUP is displayed. Use this submenu to print and/or clear
application reports, choose operation modes or values for applica-
tions which have choices and view various function logs. Each is
explained in the following steps.
2. Press the PRINT key. . .
APP is displayed. As stated in the Service menu section of the
manual, applications are enabled in the Service menu but you do
each application’s setup in this area of the Supervisor menu.
3. Press the PRINT key. . .
PLU is displayed. This stands for Product Look Up. There are 11
PLU memory channels, numbered 0-10. Each channel contains all
the parameter values and accumulator totals associated with all
the different applications. This menu item lets you print out all the
information in each channel, in all the applications, and/or clear
the information.