Model E1070 Indicator Service Manual
9. Repeat steps 6 through 8 for each sensor. . .
The last sensor number will be displayed.
10. Press the UNITS key. . .
DONE is displayed.
11. Press the ENTER. . .
BUSY is briefly displayed and then the live weight.
12. Press the ENTER key to finish the cornering process.
DONE is displayed.
13. Press SELECT key. . .
CORNER is displayed.
14. Place a weight in the center of your scale and press the UNITS key. . .
GHOST is displayed. Use this to calculate the ghost calibration
factors the ghost function will use in case a weight sensor fails.
15. Press the ENTER key to calculate the calibration factors. . .
Display shows BUSY then returns to GHOST. The display will
show ABORT if the process fails. The display will show CANT if
Ghost is not enabled under OPTION>SENSOR>GHOST in this
service menu.
16. Press the UNITS key to move to the ZERO item in the Cal menu. See
the steps for this in the earlier section, CAL submenu for analog scales.
When you are done with the SensorComm cornering and Ghost items, you
need to continue with the rest of the calibration menu. See the section after
Figure 4; ZERO (Setting Zero Reference Point).
GHOST
(Ghost Calibration Factors)
All sensors (1-4) will be dis-
played in Calibration. If the
sensor is not enabled when
you press the PRINT key, the
display will show CANT.
Downloading a configuration
file to the E1070 may corrupt
the Ghost function or cause of
the loss of Ghost calibration.

Related product manuals