EasyManua.ls Logo

Avery Weigh-Tronix evolution Series - Appendix A: Remote Display Functionality

Avery Weigh-Tronix evolution Series
131 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
113
Model E1070 Indicator Service Manual
Appendix A: Remote Display Functionality
Command Description of command
Z<LF> Emulates a Zero keypress
S<LF> Emulates a Select keypress
T<LF> Emulates a Tare keypress
P<LF> Emulates a Print keypress
U<LF> Emulates a Units keypress
F<LF> Emulates an F1 keypress
G<SP>00000<SP>lb<CR><LF> Remote display input string
G<SP>00000<SP>lb<CR><AN1> Remote display input string w/
<AN2>…<ANn><CR><LF> Annunciators <ANn> represents the
annunciator bytes that are available to
for the remote, from the host.
There should be four modes of operation for the remote display application/
setting.
Mode 1: Remote display only.
The device will be configured for Remote Display mode with/out key func-
tions. This will disable the keypad and display whatever valid message is
received from the serial port.
Mode 2:
The same as mode 1, but the addition of annunciator information will be
present in the packet from the host.
Mode 3:
The same as Mode 1, but the addition of the limited keypad functions will be
provided as well. The “remote” indicator will transmit the appropriate
characters for the given key that was pressed. See the table that defines
the packets above.
Mode 4:
The same as Mode 3, but the addition of annunciator information will be
present in the packet from the host.