EasyManua.ls Logo

Avery Weigh-Tronix evolution Series - Page 82

Avery Weigh-Tronix evolution Series
131 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
82
Model E1070 Indicator Service Manual
If the division size of the scale is less than 1, the value that is mapped will be
scaled down by 10
X
. Where X equals the number of digits to the right of the
decimal point. Any floating-point values will not be scaled down.
Example:
Token = 2 (Tare)
Type = 4 (Signed Long)
Division Size = 0.01
There are two digits to the right of the decimal point so the tare weight
coming into the indicator will be divided by 10
2
(100). If the desired tare
weight is 99.56, a value of 9956 must be sent.
Follow these steps to configure the Network/Sensorcomm status annuncia-
tor.
1. With Error displayed, press the PRINT key. . .
The current setting will be displayed. This may be Off, S-comm,
net1, or net2.
2. Use the UNITS and TARE keys to change the setting, and press the
ENTER key to accept the desired setting once it is displayed.
Off The annunciator will always remain off.
S-comm The annunciator will show the status of the Sensorcomm scale.
Red – a cell has been ghosted. Check the ghost log.
Green – a sensorcomm error has occurred. Check the error
log.
Off Scale is functioning normally.
Net1 The annunciator will show the status of network #1.
Net2 The annunciator will show the status of network #2.
Red – A network error has occurred. Check the network
settings on the indicator and PLC, and reboot the
indicator.
Green – The network connection has been established.
Amber – The network is ready for a connection, but no connec-
tion has been established.
This completes the Service menu. Press the ESC key to return to normal
weighing mode. You will be prompted to save the changes you’ve made.
Press the ESC key to abort any changes made and return to normal operat-
ing mode or press ENTER to accept them and return to normal operating
mode. BUSY flashes on the display while the unit saves data.
Error
(Error Annunciator)

Related product manuals