Figure 38: Traffic/TAWS Wiring
Installation Manual
P/N 600-00175-000 Rev 04 Traffic Sensor Wiring
- 99 -
I.2 Traffic/TAWS Sensors Wiring
EX500/600 INSTALLATION WIRING
DIAGRAM
TRAFFIC/TAWS
AVIDYNE CORPORATION
P2
45 TRAFFIC 429 A
65 TRAFFIC 429 B
9 TAWS 429 TX A
29 TAWS 429 TX B
56 TAWS 453 RX A
59 TAWS 453 RX B
P2
TAWS
429 TX #1 A
429 TX #1 B
453 TX A
453 TX B
HONEYWELL
KTA 810
54
55
HONEYWELL
KMH 820
103
104
429 RX #2 A
429 RX #2 B
95
96
9 TAWS 429 TX A
29 TAWS 429 TX B
56 TAWS 453 RX A
59 TAWS 453 RX B
TAWS/EGPWS
429 RX A
429 RX B
453 TX A
453 TX B
HONEYWELL
MK V
10A
10B
3A
3B
HONEYWELL
MK VII
13
14
15
16
MIDDLE
TOP LOWER-J1A
UPPER-J2
HONEYWELL
MK VI/ MK VIII
37
36
58
59
J1
J2
BENDIX KING
KGP-560 (GA)
47
66
30
10
J1
NOTES:
1. TERMINATE SHIELD TO P2 CONNECTOR BACKSHELL (CHASSIS GROUND).
NOTE 1