EasyManua.ls Logo

Avidyne EX600 - Figure 40: RDR-130;150;160 RADAR Direct Connect Wiring

Avidyne EX600
124 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Figure 40: RDR-130/150/160 RADAR Direct Connect Wiring
Installation Manual
P/N 600-00175-000 Rev 04 Radar Wiring
- 101 -
J.2 RDR-130/150/160 RADAR Direct Connect Wiring
28,34 GND
8 RT ON/OFF
11 TRIGGER
29 GND
16 GAIN ADJ
25 VID_INTG
13 DATA2
12 DATA1
30,31 GND
7 TEST
19 +20 VDC
21 -20 VDC
1 BORE SIGHT
9 AZ DRV
10 AZ DRV90
14 TILT ADJ
P1
GND E d
RADAR ANTENNA
RECEIVER
TRANSMITTER
(ART)
BENDIX/KING
RDR-130/150
RT-131A
P1001
BENDIX/KING
RDR-160
RT-161A
P1101
RT ON/OFF G D
TRIGGER N A
TRG SHLD P Z
GAIN HI R H(N/C)
GAIN LO S(N/C) T
DATA2 V B
DATA1 W C
DATA SHLD Z F
TEST Y E
+20 VDC H L
-20 VDC M J
BORE SIGHT F N/C
AZ DRV G R
AZ DRV90 H P
TILT ADJ L K
VID INTG U N/C
+20 VDC B N/C
-20 VDC C N/C
GND Z N/C
28 VDC IN A e
GND C h
GND D f
28 VDC IN B S
ANTENNA
J1003
POWER
P/O P1001
TO RT-131
TO RT-161
RT-131 ONLY
RT-131 ONLY
EX500/600 INSTALLATION WIRING
DIAGRAM
BENDIX/KING RADAR RDR-130/150/160
AVIDYNE CORPORATION
NOTES:
1. TERMINATE SHIELD TO P1 CONNECTOR BACKSHELL (CHASSIS GROUND).
NOTE 1
GND
28VDC
AVIONICS POWER
AVIDYNE
EX500/EX600
FLIGHTMAX MFD

Table of Contents