47
Service Manual
Plus
MICROSPEED
CKV
CDER
Derivative constant capacitor, increases the velocity
loop derivative constant.
Capacitor value that form the proportional/integral
network of the velocity Loop gain.
Standard values is 47nF, there are disabled by
opening Solder bridge S5.
Adjustments
Adjustement components
(Continued)