139
D.1.4 Regeneration resistors
Some drives are shipped with an internal regeneration resistor (see page 2). If an internal resistor is not
present, a regeneration resistor should be installed to dissipate energy during braking if a fault “1”
(over-voltage) occurs.
Baldor catalog number
M
i
n
t
D
r
i
v
e
115VAC drives 230VAC drives
M
i
n
t
D
r
i
v
e
current rating
Package size
Baldor
catalog
number
Power rating
(W)
Baldor
catalog
number
Power rating
(W)
2.5A A RG27 44 RG56 44
5A B RG27 44 RG56 44
7.5A B RG22 100 RG39 100
10A C RG4.7 320 RG10 320
15A C RG4.7 320 RG10 320
3.54
(90)
4.3 (123) for 44 watts
13.2 (337) for 320/640 watt
3.9
(100)
M4
2.6 (65)
1.7 (45)
L
L=
Dimensions: inches (mm)