CAN Bus interfaces
Unit All models
Signal - 2-wire, isolated
Channels - 2
Bit rate Kbit/s 10, 20, 50, 125, 250, 500, 1000
(800 also available on CAN bus 1 only)
Protocols - CAN bus 1: CANopen
CAN bus 2: Baldor CAN
6.1.7 Environmental
Unit All models
Operating temperature range °C °F
Minimum
Maximum
Derate
+5
+40
2.5% / °C between
40°C and 50°C (max)
+41
+104
2.5% / 1.8°F between
40°C and 50°C (max)
Storage temperature range -25 ~ +70 -13 ~ +158
Humidity
%
10~90 non-condensing according to
DIN40 040 / IEC144
Maximum installation altitude
(above m.s.l.)
m
ft
1000
Derate 1.1% / 100m over 1000m
3300
Derate 1.1% / 330ft over 3300ft
Shock - 10G according to
DIN IEC 68-2-6/29
Vibration - 1G, 10~150Hz, according to
DIN IEC 68-2-6/29