EasyManua.ls Logo

Baldor MintDrive - Analog Input, Single Ended - X11

Baldor MintDrive
155 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
28
3.2.1 Analog Input, Single Ended - X11
Location Connector X11, pins 1 & 2
Name AIN2
Mint keyword ADC.2
Description Single ended input.
Range: 0 - ±10VDC.
Resolution: 9 -bit with sign.
Input impedance: >4kΩ.
Sampling interval: 5ms.
Note: There is a +15V reference voltage supplied on X11 pin 3 from a 1.96kΩ resistor.
A linear command potentiometer of 5kΩ may be used, with X11 pin 2 connected to the wiper,
and the end terminations connected to pins 1 & 3, as shown below.
AIN2
5kΩ, 0.25W
potentiometer
or 0-10VDC
(ADC.2)
1
2
3
X11
GND
Input
Reference
Figure 10 - AIN2 analog input wiring
1
2

Table of Contents