4.3 Performance Curves—Flush Mount Models
Accuracy (90% to 6% reflectance)
Figure 36. 110 mm Models
DISTANCE (mm)
Accuracy ( ± mm)
0
0
0.25
0.50
0.75
1.00
1.25
50 100
110
35
Figure 37. 310 mm Models
0
1
2
3
4
5
6
7
9
8
10
500 100 150 200 250 300
DISTANCE (mm)
Accuracy ( ± mm)
310
35
Figure 38. 610 mm Models
DISTANCE (mm)
Accuracy ( ± mm)
0
5
10
15
20
25
30
35
0 100 200 300 400 500 600 700
Repeatability (90% to 6% reflectance)
Figure 39. 110 mm Models
DISTANCE (mm)
Repeatability ( ± mm)
0
0
0.05
0.075
0.10
0.15
0.20
0.25
0.30
0.35
50 100
35
110
Averaging = 1
Averaging = 512
Figure 40. 310 mm Models
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
500 100 150 200 250 300
DISTANCE (mm)
Averaging = 1
Averaging = 512
Repeatability ( ± mm)
35
310
Figure 41. 610 mm Models
0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
0 100 200 300 400 500 600 700
DISTANCE (mm)
Repeatability ( ± mm)
Filter = 1
Filter = 512
Q4X Stainless Steel Analog Laser Sensor
www.bannerengineering.com - Tel: + 1 888 373 6767 27