110 P/N 133487
Banner Engineering Corp. • Minneapolis, U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
SC22-3 Safety Controller
Instruction Manual
Appendix B
Edit the Configuration
• If there is a need to edit one of the properties during the
confirmation process, select Edit.
• Selecting the Edit button will open up the Properties menu for
the device. Make the change and then select OK.
If you change one or more device properties during
the manual verification stage of the confirmation, the
Controller will need to re-validate the code.
• When you complete the edit and select OK, a message will
appear asking whether you want to proceed to edit any other
devices or if you want to restart the confirmation process.
When the configuration is successfully confirmed, the Controller
will switch to Run mode, as described earlier, and wait for a
system reset.
B.7 Other Functions
Receive a Configuration from the Controller (see Section 4.5.1)
To receive (upload) a configuration from a Controller and display
it in the PCI:
• Connect the SC22-3 Controller to the PC using the USB cable
(see Section 1.3.1.).
• Apply 24V dc power to the Controller.
• Click on the Receive button in the tool bar.
Send a Configuration to the Controller (see Section 4.5.2)
To send (download) a configuration from the PCI to a Controller:
• Connect the SC22-3 Controller to the PC using the USB cable
(see Section 1.3.1.).
• Apply 24V dc power to the Controller.
• Click on the Open button in the tool bar and open the intended
configuration file.
• Click on the Send button in the tool bar.
NOTE: Confirming a configuration also sends the configuration
to the Controller.
Open a Configuration from the XM Card (see Section 4.5.3)
To open a copy of a configuration from the XM card and display it
in the PCI:
• Connect the SC-XMP programming tool to the PC using the
USB cable (see Section 1.3.1).
• Insert the XM card into the programming tool.
• Open the File menu in the upper left of the PCI tool bar.
• Select Open From XM Card.
A message will appear when the operation is complete.
NOTE: Both confirmed and unconfirmed configurations can be
sent to or received from the XM card.
Send a Configuration to the XM Card (see Section 4.5.4)
To send a copy of a configuration from the PCI to the XM card:
• Connect the SC-XMP programming tool to the PC using the
USB cable (see Section 1.3.1).
• Insert the XM card into the programming tool.
• Click on the Open button in the PCI tool bar and open
the intended configuration file.
• Open the File menu in the upper left of the PCI tool bar.
• Select Send To XM Card.
A message will appear when the operation is complete.
NOTE: Both confirmed and unconfirmed configurations can be
sent to or received from the XM card.
Lock the XM Card (see Section 4.5.5)
To Lock the XM card so that the stored configuration cannot be
changed (this operation cannot be undone):
• Insert the XM card into the programming tool.
• Click on the Open button in the PCI tool bar and open
the intended configuration file.
• Verify that the correct file is stored on the XM card.
• Open the File menu in the upper left of the PCI tool bar.
• Select Lock XM Card.
A message will appear when the operation is complete.
Change the Controller Password (see Section 4.5.6)
To change a Controller password from the PCI:
• Connect the Controller to the PC, using the USB cable.
• Apply 24V dc power to the Controller.
• Open the File menu in the upper left of the PCI tool bar.
• Select Change Safety Controller Password.
• Fill in the menu that will appear as needed.
• Record the new password and click OK.