Appendix
V-Controller (BUS 6 VC) 103
Baumüller Nürnberg Electronic GmbH & Co. KG 5.03047.01
X P006 RFG input 3 0,00 % ±100,00 % = ±16383 dec 69
X P007 RFG ramp-up time 3 0,00 s 1,00 s = 100 dec 69
X P010 RFG ramp-down time 1 0,00 s 1,00 s = 100 dec 69
X P011 RFG ramp-down time 2 0,00 s 1,00 s = 100 dec 69
X P012 RFG ramp-down time 3 0,00 s 1,00 s = 100 dec 69
X P013 RFG mode 0001 1:1 69
X P016 RFG rounding 0 s 1000 ms = 1000 dec 69
X P057 N P gain 10,0 10,0 = 100 dec 45
X P058 N integral action time 25,0 ms 25,0 ms = 250 dec 46
X P061 N limiter control deviation 99,99 % 100,00 % = 16384 dez 46
X P080 I P gain 1,0 10,0 = 100 dec 42
X P081 I integral action time 2,5 ms 1000,0 ms = 10000 dec 42
X P090 PU mode 0000 1:1 34
X P103 PWM frequency 8,0 kHz 8,0 kHz = 80 dec 41
X P116 PU I limit 2,5 A 100,0 A = 1000 dec 36
X P119 PU overload time - 10,00 S = 1000 dec 35
X P122 M set operation mode -3 1:1 52
X P125 M mode 0 1:1 52
X P126 M communication source 0000 1:1 53
X P127 M communication monitoring 0000 1:1 53
X P128 M monitoring time 0 ms 1000 ms = 1000 dec 53
X P129 M monitoring code 0 1:1 54
X P140 SVG target Pxxx 0 1:1 72
X P142 SVG set value 1 100,00 % ±100,00 % = ±10000 dec 72
X P143 SVG set value 2 0,00 % ±100,00 % = ±10000 dec 72
X P144 SVG set value 3 -100,00 % ±100,00 % = ±10000 dec 72
X P145 SVG set value 4 0,00 % ±100,00 % = ±10000 dec 72
X P146 SVG time 1 1,000 s 1,000 s = 1000 dec 72
X P147 SVG time 2 1,000 s 1,000 s = 1000 dec 72
X P148 SVG time 3 1,000 s 1,000 s = 1000 dec 72
X P149 SVG time 4 1,000 s 1,000 s = 1000 dec 72
X P166 OS state - 1:1 65
X P277 AI 1 input channel 0 1:1 74
X P278 AI 1 smoothing 1 ms 1:1 74
X P279 AI 1 scaling 1,00 ±2,00 % = ±200 dec 75
X P280 AI 1 target Pxxx 0 1:1 75
X P281 AI 1 offset 0,00 % ±100,00 % = ±10000 dec 75
X P282 AI 1 threshold value 0,00 % +100,00 % = +10000 dec 75
X P284 AI 2 input channel 1 1:1 74
X P285 AI 2 smoothing 1 ms 1:1 74
X P286 AI 2 scaling 1,00 ±2,00 % = ±200 dec 75
X P287 AI 2 target Pxxx 0 1:1 75
X P288 AI 2 offset 0,00 % ±100,00 % = ±10000 dec 75
X P289 AI 2 threshold value 0,00 % ±100,00 % = ±10000 dec 75
X P302 AI state - 1:1 74
Parameter Default Internal scaling Page
X: Parameter is saved in the data record