Malfunction
-
Leakage of grease at the
pressure relief valve
-
The red indicator pin at the
malfunction indicator of the
pump element is visible
-
The LEDs in the inspection
window of the control flash
-
Level error, although the
reservoir is filled with
lubricant
-
Level error although there
is no level monitoring in the
pump
- The pump function (pump
operating time or cycle
time) does not correspond
to the values adjusted in
the inspection window of
the control unit
Cause
-
Excessive pressure in the
system
-
Progressive distributor
blocked
-
System blocked
-
Defective valve spring
-
Excessive system pressure
-
Pump lubricates
-
Grease level error
-
Excessive pressure error
-
Speed error
-
Stroke error
-
CPU/memory error
-
Capacitive proximity switch
in the reservoir defective
-
Cable of the level
monitoring defective
-
Level monitoring activated
in the control unit
-
The operating mode or the
adjustment range of the
control has been changed,
but the sticker in the
inspection window not
Remedy
-
Check the system
-
Replace distributor
-
Repair blocked bearing
point
-
Renew the pressure relief
valve
-
See „Leakage of grease at
the pressure relief valve“
-
No error (see signals)
-
Fill reservoir
-
Check the system and
repair it, if necessary
-
Check the system and
repair it, if necessary
-
If there is no
defectiveness, activate
intermediate lubrication
once or twice
-
Exchange the control unit
-
Send the lubricant
reservoir with level
monitoring in for being
repaired
-
Exchange the cable
-
Deactivate level monitoring
in the control unit with the
system diagnosis software
BEKA-DiSys
- Make a diagnosis with the
diagnosis software
- BEKA-DiSys
- Adapt the adjustment to
the sticker in the
inspection window or
exchange the sticker
46