EasyManuals Logo

BENSHAW RSi SG Series User Manual

BENSHAW RSi SG Series
218 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #67 background imageLoading...
Page #67 background image
5-1
Chapter5. ParameterList
5.1 DRV(DriveGroup)ParameterList
[DRV Group]
PARAM Description
LCD Keypad
Display Setting Range
Factory
Default
Adj.
During
Run Page
DRV-00
(Notes 1 & 2)
Main Display
DRV>K/K 0.0 A
00 STP 0.50Hz.
0 - (FUN-30)
Hz.
0 Yes 6-1
DRV-01 Acceleration Time
7.5~125HP
Acc. time
0 - 6000 secs. 20
Yes 6-1
150~700HP
Acc. time
0 - 6000 secs. 60
DRV-02
Deceleration Time
7.5~125HP
Dec. time
0 - 6000 secs. 30
Yes 6-1
150~700HP
Dec. time
0 - 6000 secs. 90
DRV-03
Drive Mode
(Run/Stop Method)
Drive mode
Keypad
Fx/Rx-1
Fx/Rx-2
Int. 485
Fx/Rx-1
No
6-1
DRV-04
Frequency Mode (Frequency
setting method)
Freq mode
Keypad-1
Keypad-2
V1
V1S
I
V1+I
Pulse
Int. 485
Ext. PID
Keypad-1
No 6-2
DRV-05 Rated Motor Current
Rated-Curr
1.0 - 999.9
Amps
Model
Dependent
No 6-2
DRV-06 Electronic Thermal Selection
ETH select
No, Yes Yes Yes 6-3
DRV-07
Electronic Thermal Level for 1
Minute
ETH 1 min
DRV-08 -
200%
130 Yes 6-3
DRV-08
Electronic Thermal Level
Continuous
ETH cont
50 - DRV-07 % 100 Yes 6-3
DRV-09
Characteristic Selection
(Motor Type)
Motor type
Self-cool
Forced-cool
Self-cool Yes 6-3
DRV-10 Output Current
Current
Amps Amps View Only 6-4
DRV-11 DC Link Voltage
DC link Vtg
Volts Volts View Only 6-4
DRV-12 User Display Selection
User disp
Voltage
kiloWatts
Volts View Only 6-4
DRV-13 Present Trip Display
Fault
None View Only 6-4
DRV-14 Motor Speed
Speed
rpm rpm View Only 6-5
DRV-15
Target/Output
Frequency Display
TAR 0.00 Hz
OUT 0.00 Hz
Hz., RPM Hz. View Only 6-5
DRV-16
(Note 3)
Reference/Feedback Frequency
Display
REF 0.00 Hz
FBK 0.00 Hz
Hz., RPM Hz. View Only 6-5
DRV-17 Hz/Rpm Display
Hz/Rpm Disp
Hz., RPM Hz. Yes 6-6
DRV-18
(Note 3)
PID Parameter
R 0.0 Hz T 0.0 Hz
F 0.0 Hz O 0.0 Hz
Hz. View Only 6-6
DRV-19 AD Parameter
V1 0 V2 0
V1S 0 I 0
View Only 6-6
DRV-20
(Note 4)
EXT-PID Parameter
R 0.00% O 0.00%
F 0.00% DRV 20
View Only 6-6
DRV-21
(Note 5)
Step Frequency 1
Step Freq-1
0 - (FUN-30)
Hz.
10 Yes
6-6
DRV-22 Step Frequency 2
Step Freq-2
20 Yes
DRV-23 Step Frequency 3
Step Freq-3
30 Yes

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BENSHAW RSi SG Series and is the answer not in the manual?

BENSHAW RSi SG Series Specifications

General IconGeneral
BrandBENSHAW
ModelRSi SG Series
CategoryDC Drives
LanguageEnglish