38 - IANUS BT 300 KIT - IANUS BT 500 KIT
D812457 10550_02
ON ON
OFF OFF
123456789101112
13
1415161718192021222324252627
5
4
3
2
1
RX
2
1
TX
1 2 3 4
ON
5 6 7 8 9 10
VSAFE ~(+)
VSAFE ~(-)
24V ~(+)
0V(-)
25W max.
N
L
89101112131415161718192021222324252627
OPEN
COM
COM
STOP
PHOT 1
PHOT 2
FAULT PHOT 1
FAULT PHOT 2
NO
NC
NC
NO
NC
NO
ANT
START
NO
1 2 3 4
ON
5 6 7 8 9 10
1 2 3 4
ON
5 6 7 8 9 10
1
3
2
During installation, the power cable must be stripped to allow the earth wire to be connected to the relevant terminal, while leaving the live wires as short as possible�
The earth wire must be the last to be pulled taut in the event the cable's fastening device comes loose
If the gate is installed in a public area or if the TCA is included (automatic closing time),
photocells must be installed�
To improve user safety, their installation is recommended�
QUICK START
Warning: cut o power
before any operation!!!!
Secure the wire in the wire clamp
Connect the EARTH protection wire
YELLOW - GREEN
Connect the PHASE (L) and NEUTRAL (N)
wires
MAINS CONNECTIONS
PHOTOCELL CONNECTIONS