EasyManua.ls Logo

Blodgett HV-100EM - Page 38

Blodgett HV-100EM
39 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5
5
4
4
3
3
2
2
1
1
D D
C C
B B
A A
HEAT_CONTACTOR[1..2]
24Vac [0..2]
24VAC_2[0..2]
24VAC_2[ 0..2]
RD/BK–2[1..2]
RD/ BK1[ 1..2]
GY/ BK1[1..2]
Hi_Lim it _Trip_H
Drv_Faul t_L
Mt r_Rev_Ena_L
Mt r_Spd_ Sel_Bit_0_Ena_L
Mt r_Fwd_Ena_L
Mt r_Spd_ Sel_Bit_1_Ena_L
Drv_Inpu t _Com
Mt r@Set Spd_L
BR–6
BK–3, 24VDC_RTN
RD3, 24VDC
Light_Pwr
Cavi ty_Vent _Rt n
BL–6
BR6
BL–6
Title
DRAWINGNUMBE R REV
SHEET
OF
THIS DRAWING IS THE PRO PERTY OF G. S. BLODGETT CORPO RATION. NEITHER THISDRAWING
NOR ANY INFORMATION CONTAINED H EREIN M AY BECOPIED ORUSED, IN WHOLE ORIN PART,
WITHO UT THE EXPRESSWRITTEN PERMISSION OF THE G.S. BLODGETT CORPORATION.
G. S. BLODGETT CORPORATION. UN PUBLI SHED WORK. AL L RIGHTS RESE RVED
50 LAKES IDE AVE . BURLIN GTON, VERMONT 05401
G.S.BLODGETTCORPORATION
SCALE
DATE
DWG
BY
DATE
APR
BY
GAGE
M ATL
TOLERA NCES UNLESS OTHERWI SESPE CIFIED
.XXX .XX ANGULAR HOLE
.015 .03 1 .005
REV ECN ETADSNOISIVE YBRPAR
53512 C
SCHEMATIC, HV100EM 440V 14KW MENUSE LECT
33MH
MH
09–13–10
09–13–10 NONE
B
B1 0–158
MH
11–10 10
DRIVE AND SHIELDED CABLE TO MOTOR AND COM
NEW TI TLE BLOCK; ADDED EMI FILTER TO M OTOR
C
B1 2–011
CHAN GED J19 TO J7 TO M ATCH I NTERFACE BOARD.
I MPROVED DEPI CTI ON OF INVERTER DRIVEWIRING.
03–23 12
MH
___ ___
__–__–__
___
___–___
__–__–__
___
52185
R11092
24Vdc Power Supply
+
L
N
Gnd
BR–1, 14awg, 600V
BL–1, 14awg, 600V
BL–2, 14awg, 600V
BR–2, 14awg, 600V
GR/Y1
BK
OR
BK–5
OR–6
38605
BL–3, 22awg, 600V
BR–3, 22awg, 600V
WH–1, 10awg, 600V
BK–1, 10awg, 600V
RD–1, 10awg, 600V
RD–2
WH–2
BK–2
RD–3
WH–3
BK–3
OR–5, 22awg, 300V
Cavity Hi_Limit
L1
+
L2
L3
T1
T2
T3
Trip Coil
Fast Trip Curve
M9608
36441
RD/WH–1, 22awg twisted pair
RD/WH–2, 22awg twisted pair
BR–4, 22awg, 600V
BL–4, 22awg, 600V
2X Fuse, 7A
51455
51454
51453
25 A
440V configuration
DRKB
WH BK
WH
RD
52446
OR/BK–1
RD/WH–3, 22awg twisted pair
RD–3
WH–3
RD–1
WH–1
RD–2
WH–2
RD–9, 14awg, 600V
WH–9, 14awg, 600V
RD–8, 14awg, 600V
WH–8, 14awg, 600V
RD–6/RD–3
R
BK–3
Bk BK, 200
, 18awg
RD, 200
, 18awg
50956
22awg twisted pair
Bk
R
T.B. Oven, Rear
D0119 (X 2)
BK–22
22awg twisted pair
R
Bk
RD–5
24356
14awg, 600V
14KW Heating Element Assembly
53016, 220V, 2.33KW (X6) 14KW total , 19A nominal
52717
GR/Y–2
BK12
GYIN3
V–11
binary select:
GYIN4
BK
Pre_Set Speeds:
RD
BK–12/BK–13
GYIN2
BL16
BK–L
GY
52680
Programmed
Yaskawa
J1000
INVERTER
DRIVE
GY(GY/BK–1)
A20: 000 – V_Lo_Spd Freq = 20hz
BL–6
GY19
GY/BK–1 twisted pair
WH
GY
GYIN1
GY14
BKBK
GY17
18awg, 600v
Shielded Cable
GR/Y–2
A23: 011 – V_Hi_Spd Freq = 50hz
GY
BK–L/CM2
GYIN5
GY/BK–1 twisted pair
BR16BR–6
BKCM2
GY20
A21: 001 – Lo_Spd Freq = 30hz
BK13
BK
Shield Wire
Shield Wire
GY15
GY(GY/BK–1)
BK(GY/BK–1)
BL
WH
GY18
A22: 010 – Hi_Spd Freq = 40hz
150W, 400 OHM
BK(GY/BK–1)
TB2
Ter m_Blk_AC_Gnd_3p
L1_A
L1_B
Gnd_ A
Gnd_ B
L2_A
L2_B
L1_C
L1_D
Gnd_C
Gnd_D
L2_C
L2_D
T1
Transfo rm er_Mult itap
1
2
3
CB2
K1
Heat Cont actor
1
L1
2
L2
3
L3
6
T3
5
T2
4
T1
7
A1
8
A2
CB1
15 Amp
A2A1
L1
LINE
LOAD
N
N
L1
GND
EM I FILTER
53902
MTR1
Cir_Mtr , 3p, 4 pole
39332
L1
L2
L3
Gn d
Halogen Lamp–12V
1
2
52706
BRAKING RES ISTOR
S1
S2
S3
S4
S5
SC
A1
+V
AC
AM
AC
MA
MB
MC
W/T3
V/T2
U/T1
B1
B2
R/ L1
S/L2
SW4
Cavi ty_Hi _Lm t
F2
FUSE HOLDER
1
2
K1_Aux
T1
TRANSFORMERPOWER, STEPDOWN
0IN
0OUT
220V
380V
440V
480V
CON4
TB1
Fi eld Wiring Term Bl k
1_A
1_B
2_A
2_B
3_A
3_B
1_C
1_D
2_C
2_D
3_C
3_D
Gnd_ 1 Gnd_ 2
1
2
3
4
5
6
7
8
9
10
11
12
1
2
3
4
5
6
7
8
9
10
11
12
N. C.
1 2
F1
TB3
Term_Blk_3p
L1_A
L1_B
L2_A
L2_B
L3_A
L3_B
L1_C
L1_D
L2_C
L2_D
L3_C
L3_D

Other manuals for Blodgett HV-100EM