MARK V
3-9
INTELLITOUCH II CONTROL
To access 2nd level programming and diagnosĆ
tics
1. The display reads SELECT. Press CLEAR 1, 2,
3, 4, 5, 6, ENTER.
2. The display reads CODE-? Press 1, 2, 3, 4, 5,
6 ENTER.
3. The display reads ACCESS.
To run LED diagnostics
1. Press CLEAR 1, 1, 1 ENTER.
2. The control runs selfĆdiagnostics on each LED
individually. When all of the LED's light togethĆ
er press the CLEAR key.
3. The display flashes EXIT then ACCESS.
To check the software configuration
1. Press CLEAR 1, 2, 3 ENTER.
2. The display lists the software configuration inĆ
formation.
3. The display flashes EXIT then ACCESS.
OVEN CALIBRATION
1. Press CLEAR, TEMP, TEMP, TEMP, ENTER.
Temperature display scale
2. The display flashes _F/_C then MODE-?
3. Press any key to toggle the scale from _F to _C.
4. Press the PROG/ENTER key to lock in new
scale.
5. The display flashes T'_F ( or T'_C).
Temperature offset
1. Once the temperature scale has been proĆ
grammed, the display flashes either POS *
OFFSET or NEG * OFFSET
NOTE: POS OFFSET is displayed if a value has
been programmed in for a positive offĆ
set. NEG OFFSET is displayed if a valĆ
ue has been programmed for a negaĆ
tive offset. The only time both will be
displayed is if a value of 0 has been enĆ
tered for both.
2. Enter a value for the desired offset. The display
flashes DISPLAY * INTEG?.
3. Press the PROG/ENTER key. The default value
of 30 will be displayed.
4. Press the PROG/ENTER key. The display will
flash TĆCTRL * INTEG?.
5. Press the PROG/ENTER key. The default value
of 10 will be displayed.
6. Press the PROG/ENTER key.
Ready Band
1. The display flashes READY, BAND and POS.
2. Use the numeric keys to enter a value between
1 and 25. Press the PROG/ENTER key.
3. The display flashes READY, BAND and NEG.
4. Use the numeric keys to enter a value between
1 and 25. Press the PROG/ENTER key.
To exit oven calibration
1. The display flashes ACCESS, DONE and EXIT.