CALIBRATION AND ADJUSTMENT
3-10
BLODGETT IQ CONTROL
NOTE: For error code display information see
page 4-3 of the Troubleshooting section.
2ND LEVEL PROGRAMMING
Entering the programming mode
1. Press the prog key. The top display reads
CodE.
2. Use the product keys to enter the programĆ
ming access code: 4 5 1 2. Press the enter key.
The top display reads SYS.
Programming hold
1. Press the scan key. The top display reads
Hold. Press the toggle/clear key to toggle beĆ
tween YES and no. Press the scan key.
If no is chosen:
A.) The controller advances to programming
the setback mode.
If yes is chosen:
A.) The top display reads AUTO. Press the
toggle/clear key to toggle between YES
and no. Press the scan key to enter the deĆ
sired hold mode.
B.) The top display reads HOLD. The bottom
display flashes the current hold time. Use
the product keys to enter the desired hold
time. Press the scan key to enter the new
hold time.
C.) The top display reads HOLD. The bottom
display flashes the current hold temperaĆ
ture. Use the product keys to enter the deĆ
sired hold time. Press the scan key to enter
the new hold temperature.
D.) The top display reads FAn. The bottom disĆ
play gives the current fan mode. To
change the fan mode press the toggle/
clear key. The bottom display toggles beĆ
tween Hi and Lo. Press the scan key to enĆ
ter the new fan mode and continue with
programming the setback mode.
Programming the setback mode
1. The top display reads SEtb. The bottom disĆ
play gives the setback mode. To change the
setback press the toggle/clear key. The botĆ
tom display toggles between YES and no.
Press the scan key.
If no is chosen:
A.) The controller advances to programming
the temperature mode.
If yes is chosen:
A.) The bottom display gives the current setĆ
back time. Use the product keys to the enĆ
ter the desired setback time. Press the
scan key to enter the new setback time.
B.) The bottom display gives the current setĆ
back temperature. Use the product keys
to the enter the desired setback temperaĆ
ture. Press the scan key to enter the new
setback and continue with programming
the temperature mode.
Programming the temperature mode (_F or _C)
1. The top display reads dEg. The bottom display
gives the units. To change the units press the
toggle/clear key. The bottom display toggles
between F and C.
2. Press the scan key to enter the new temperaĆ
ture units and continue programming the oven
size.
Programming the oven size
1. The top display reads APPL. The bottom disĆ
play reads either FULL or HALF. Press the
toggle/clear key until the bottom display reads
FULL for the Mark V.
2. Press the scan key to enter the oven size and
continue with exiting the programming mode.
Exiting the programming mode
1. The top display reads SYS. Press the prog key.
The control returns to the operating standby
mode.