Receiver No. Option Address Default
1 Transmission format for receiver (0 = not
used, 1 = CID, 2= SIA, 3 = Conettix IP, 4 = SIA
DC 09, 5 = SIA DC09 (2x ID))
0023 1
Telephone number / IP address and port (0 –
9, 11 = *, 12 = #, 13 = pause, 15 = terminal)
0000 – 0016 15
Subscriber ID number (0 - 9 = 0 - 9, 11=B,
12=C, 13=D, 14=E, 15=F)
0017 – 0022 000000
Anti-replay for receiver (0 = disabled, 1 =
enabled)
0024 1
EN=1
Acknowledge wait time for receiver (05 - 99
seconds )
0025 – 0026 05
Network polling time for receiver (001 - 999
minutes )
0027 – 0029 001
DC09 data format (1 = ADM-CID, 2 = SIA-
DCS)
0140 1
DC09 acct1 length (3 – 16, all other input is
treated as “3”)
0141 – 0142 06
DC09 acct1 (0 - 9 = 0 - 9, 10=A, 11=B, 12=C,
13=D, 14=E, 15=F)
0143 – 0158 000001
000000
0000
DC09 acct2 length length (3 – 16, all other
input is treated as “3”)
0159 – 0160 06
DC09 acct2 (0 - 9 = 0 - 9, 10=A, 11=B, 12=C,
13=D, 14=E, 15=F)
0161 – 0176 000001
000000
0000
DC09 Lpref (0 - 9 = 0 - 9, 10=A, 11=B, 12=C,
13=D, 14=E, 15=F)
0184 – 0189 000000
DC09 Rrcvr enable (0 = disabled, other =
enabled)
0177 0
DC09 Rrcvr (0 - 9 = 0 - 9, 10=A, 11=B, 12=C,
13=D, 14=E, 15=F)
0178 – 183 000001
2 Transmission format for receiver 0053 1
Telephone number / IP address and port 0030 – 0046 15
Subscriber ID number 0047 – 0052 000000
Anti-replay for receiver 0054 1
EN=1
Acknowledge wait time for receiver 0055 – 0056 05
Network polling time for receiver 0057 – 0059 001
DC09 data format 0260 1
AMAX panel Address Programming | en 111