When the report is transmitted with Conettix IP Communication, some reports might be
missed. It is recommended not to separately use the ITS-DX4020-G module. If the ITS-DX4020-
G module is used, other network modules (e.g. B426) or the public telephone network can be
set as backup channel to ensure that no reports are missed.
The communication path of B426 / ITS-DX4020-G / B 450 is as follows:
Module Address Setting Corresponding
Communication Path
Module 1: B426 module 1 / ITS-
DX4020-G / B 450
134 Paths 1 and 2
Module 2: B426 module 2 / B450 250 Paths 3 and 4
Only when IP module 1 is used and set to paths 1 to 4, the report can be sent to those paths.
Remote Access
The AMAX panel supports remote programming via USB, telephone, or IP network using the
software A-Link Plus. The following option can be performed:
Setting the date and time
Uploading / downloading programming parameters
Remote arming / disarming of each area
Enabling / disabling the alarm siren of each area
Enabling / disabling each output
Remote Access Armed
This option enables / disables the remote access for the function alarm.
Remote programming
This option enables / disables the remote access for programming. If this function is
disabled, the system can not be programmed via an IP network anymore.
Remote PC
IP Address and port number
RPC IP address is a fixed IP address for remote programming software.
RPC port number is the port number for remote programming.
How to program an IP address and port:
1. Program an IP address with 17 digits: digits 1 - 12 for the IP address and 13 - 17 for the
port.
2. Use no punctuation in the IP address.
3. If any unit of the IP address has less than 3 digits, use 0 to fulfill the data in the higher
bits.
4. The remaining 5 digits program the port. Port number ranges from 0-65535.
5. If a port number has less than 5 digits, use 0 to fulfill the data.
Example
4 To program the IP address “10.16.1.222:80”, enter the following sequence into the
correspondent address:
[0 1 0 0 1 6 0 0 1 2 2 2 0 0 0 8 0]
6.1.5
6.1.6
46 en | Settings AMAX panel
2015.05 | 06 | F.01U.309.277 Installation Manual Bosch Sicherheitssysteme GmbH