1. AC power failure to the repeater.
2. The repeater is not wired correctly, if a wireless module is enabled.
Restore:
4 Restore the repeater AC power and reset the fault.
Supervise:
1. Report the repeater AC power fault to configured destination when the fault is detected.
Slow flash FAULT indicator (refer to Keypad Indicators, page 8 for a detailed description).
2. When the fault is reset, send the restored report to the configured destinations.
P The FAULT indicator is turned off when there is no other system fault.
– RF Repeater 1-8 Battery Failure
Condition:
The repeater is in a low battery condition if a wireless module is enabled.
Restore:
4 Restore the repeater battery and reset the fault. For more information refer to RF Devices,
page 83.
Supervise:
1. Report the repeater battery fault to configured destination when the fault is detected.
Slow flash FAULT indicator (refer to Keypad Indicators, page 8 for a detailed description).
2. When the fault is reset, send the restored report to the configured destinations.
P The FAULT indicator is turned off when there is no other system fault.
– RF Sensor Power Failure
Condition:
The sensor is in a low battery condition if a wireless module is enabled.
Restore:
4 Restore the sensor battery and reset the fault. For more information refer to RF Devices,
page 83.
Supervise:
1. Report the sensor power fault to configured destination when the fault is detected.
Slow flash FAULT indicator (refer to Keypad Indicators, page 8 for a detailed description).
2. When the fault is reset, send the restored report to the configured destinations.
P The FAULT indicator is turned off when there is no other system fault.
– RF Keyfob Battery Failure
Condition:
The keyfob is in a low battery condition if a wireless module is enabled.
Restore:
4 Restore the keyfob battery and reset the fault. For more information refer to RF Devices,
page 83.
Supervise:
1. Report the keyfob battery fault to configured destination when the fault is detected.
Slow flash FAULT indicator (refer to Keypad Indicators, page 8 for a detailed description).
2. When the fault is reset, send the restored report to the configured destinations.
P The FAULT indicator is turned off when there is no other system fault.
3 -Output Failure
– Onboard Output 1-2 Fault
152
en | Troubleshooting AMAX panel
2015.05 | 06 | F.01U.309.277 Installation Manual Bosch Sicherheitssysteme GmbH