Hardware
2--19
1070 072 196-101 (00.06) GB
2.6.2 Example of a Configuration File
; Configuration file COM-E Project XY of 6-12-98.
; -----------------------------------------------
; Comments are marked with a ’;’
; Spaces and tabulators serve as delimiters.
; Communication parameters
; ------------------------
Retransmissiontimer: 500 ; Time in milliseconds (default: 200 ms)
Retransmissioncounter: 8 ; default 16
Retransmissionmode: 0 ; 0 = constant repeat time (default)
; 1 = increasing repeat time (with each
; repeat, the time is doubled)
; List of communicating stations
; ------------------------------
; static part of the ARP table, i.e. the list of stations
; This table has a permanently set structure with:
; Ip-Adr. <TAB/Blank> logical name <TAB/Blank> Ethernet address ;Comment
; The logical name may have a maximum of 31 characters
; During centralized programming, the controller can be selected under this
; name.
IP-Table:
142.2.20.10 ESP001 20-af-91-23-23-66 ; John
142.2.20.11 ESP002 07-71-ab-c7-12-36 ; Fred
142.2.20.12 ESP003 13-45-66-77-54-24 ; Stan
142.2.20.20 COM-E_1 00-60-34-00-20-00 ; In the back of the hall to the left
142.2.20.21 COM-E_2 00-60-34-00-20-01 ; Main control
142.2.20.22 COM-E_3 00-60-34-00-20-02 ; Output
142.2.20.43 COM-E_4 00-60-34-00-20-03 ; ..
142.2.20.44 COM-E_5 00-60-34-00-20-04 ; ..
Ethernet-Overwrite: 1 ;Overwriting of the impressed Ethernet address
; with entry from the IP table
; For the dynamic part of this table, the following data can be preset:
; IP lifetime determines how long a dynamic entry in the ARP table remains valid.
; A job with this address retriggers the timer.
IP-Lifetime: 120 ; time in seconds
; Default-Routing
; ---------------
; Client commands whose target IP address is located in another subnetwork
; are generally sent to the default gateway.
Subnet-Mask: 255.255.0.0
Default-Gateway:142.2.1.100
; Login
; -----
; For a controller - controller communication, a login is not required.
; If a PC or another device is connected, this communication
; reference must be first released with a password if it is
; defined in the configuration file.
; The password can be changed from the PG (programming unit).
Password: John