2.8 Technical Data
Technical Data COM-E
Interfaces D V.24/20 mA as per guideline ”VDI
2880 Blatt 2”
D 20mA interface is electrically iso-
lated
Baudrates V.24/20 mA interface 600 to 57600 bd
Current uptake internally
D 5V voltage supply 500 mA typical
D +12V ISO voltage supply 70 mA + 20 mA per active current loop
Resistance against conducted interfer -
ences
As per EN 61 131-2
Max. number COM-E per controller 5
Ambient temperature range 0to+55C
Storage temperature range -- 2 5 t o + 7 0 C
Width 1slot
Weight 300 g
Protection degree Protection degree IP20 as per DIN
VDE 0470-1, installed in housing
Place and way of installation The COM-E can, if inserted in a card
rack, be installed in a control cabinet
horizontally or vertically (if the ambient
temperature is reduced to 40 C).