General Information Regarding BUEP-E and BUEP19E
7--3
1070 072 196-101 (00.06) GB
7.1.1 Protocol-Independent Parameters
Job activation of the protocol-independent parameter is done via the
R5REQ module.
PW1
Parameter
Word
Attribute Description
PW1 W Result of the job
This is where after each module call the error message is passed over. The
low byte contains the error code and the high byte the proposed PLC reac-
tion.
High Byte Low Byte
Code
[hex]
PLC reaction Code
[hex]
Error code
00 Job has been passed to RSS without error 00 Job has been passed to RSS without error
01 Call R5REQ again 01 Job is already being processed
02 Change PLC program 02 Job is in queue
03 Change protocol parameter 03 Job is acknowledged, but not yet confirmed
04 Execute R5INIT again 04 Wrong channel number
05 Execute R5REQ again 05 Wrong RSS number
06 Execute R5CON again 06 Wrong job number
07 Reload V.24 protocol 07 Abortion of job not possible
08 Check system configuration 08 No free job number on the RSS
10 RSS 0 not initialized
11 RSS 1 not initialized
12 RSS 2 not initialized
13 RSS 3 not initialized
14 RSS 4 not initialized
20 RSS 0 not listed in SK table
21 RSS 1 not listed in SK table
22 RSS 2 not listed in SK table
23 RSS 3 not listed in SK table
24 RSS 4 not listed in SK table
30 Communication error on the RSS
31 Communication error on the ZS
92 Invalid command parameter
D0 No protocol for channel 0 (V24 channel) loaded
D1 Job queue is full