General Information Regarding BUEP-E and BUEP19E
7--4
1070 072 196-101 (00.06) GB
PW2
Parameter
Word
Attribute Description
PW2 W RSS and channel number
This word contains the information on which COM-E and via which channel
this job is supposed to be processed.
High Byte Low Byte
RSS number Channel number
PW3
Parameter
Word
Attribute Description
PW3 W Job number
At the computer interfaces of the CL400 / CL500, it is possible to start up to
16 jobs in parallel. By indicating the job number, the jobs can be distin-
guished. Another job with the same job number can only be started when the
old one is finished. Such an attempt during a running job will be rejected by
the R5REQ with an error message.
Starting more than one centralized job with different job numbers in a PLC
cycle though is possible.
XXXX
15 8 7 0
XXXX XXXX XXXX
34
12 11
Job number
0 to 16#FFFFH
0--Startjob
1 -- Delete job from queue
The job numbers 12 to 15 are reserved for high-priority jobs. Such an indica-
tion on the parameter has the effect that this parameter is given high priority
and that it is processed accordingly.