General Information Regarding BUEP-E and BUEP19E
7--17
1070 072 196-101 (00.06) GB
7.4 Password
BUEP-E enables several clients to access the controller via the COM-E
module. This can be preferred in many cases, but it can also lead to prob-
lems. Therefore, a password function is provided for protection.
. The default password is: BoschPlcSystems
The PG knows this password and tries to log in automatically. If the pass-
word has not been altered, the programmer will not even notice that a pass-
word exists. If the password has been changed, communication with the
controller in the PG is only possible after correct password confirmation. The
password can be altered via the configuration file or the programming unit.
The password verification is only active for writing commands and/or outputs
(A) into the controller.
. A password can only be reset if the reset button on the relevant COM-E
module is pushed during switch-on.