4.2.2 Output Parameters
Parameter Attribute Description
P5 W Result
This parameter transmits the result of the initialization to the PLC program
and signalizes errors that have come up.
Code
[hex]
Explanation
0000 Initialization finished without errors
0001 No RSS according to parameter 0 available
0002 No RSS according to parameter 1 available
0004 No RSS according to parameter 2 available
0008 No RSS according to parameter 3 available
0010 No RSS according to parameter 4 available
0020 No free memory area available for memory management list
0021 No data field addresses in the memory management list
0030 Communication error on the RSS
0031 Communication error on the ZS