Figure 4.5: Example with discussion units (DCN-DISS)
Socket Extension cable Power for devices Corrected power
Trunk 1 40 m 69.9 W 83.9 W
Trunk 2 20 m 76.8 W 83.8 W
Trunk 3 15 m 79.6 W 84.9 W
Table 4.3: Example with discussion units (DCN-DISS)
The example above is within system limits because:
4.1.7
Conference System Planning | en 71
Bosch Security Systems B.V. Operation Manual 2013.11 | V2.0 | DCN-NG_OM_V4.x