Function
code
Name Setting range
Min.
unit
Factory
default
Attribute
E2.16 Multi-speed frequency 7 0.00 ~ [b1.06] 0.01 Hz 0.00 Hz
RUN/
STOP
E2.17
~
E2.19
Reserved
Simple PLC basic control
Function
code
Name Setting range
Min.
unit
Factory
default
Attribute
E2.30
Simple PLC
running mode
0: No action
1: Mode 1
2: Mode 2
3: Mode 3
1 0 STOP
E2.31
Simple PLC
time multiple
1 ~ 60 1 1 STOP
E2.32
~
E2.34
Reserved
PLC stage control
Function
code
Name Setting range
Min.
unit
Factory
default
Attribute
E2.35 Stage 0 action selection
011, 012, 013, 014
021, 022, 023, 024
031, 032, 033, 034
041, 042, 043, 044
111, 112, 113, 114
121, 122, 123, 124
131, 132, 133, 134
141, 142, 143, 144
1 011 STOP
E2.36 Stage 0 running time 0.0 ~ 6000.0s 0.1s 20.0s STOP
E2.37 Stage 1 action selection
See "Stage 0 action
selection"
1 011 STOP