Do you have a question about the Bowa ARC 350 and is the answer not in the manual?
Manufacturer | Bowa |
---|---|
Model | ARC 350 |
Max. Output Power | 350 W |
Mains Frequency | 50/60 Hz |
Input Frequency | 50/60 Hz |
Category | Medical Equipment |
Mains Voltage | 230 V |
Input Voltage | 230 V |
Insulation Class | Class I |
Explains warning instruction format, risk types, and prevention measures.
Details risk levels (DANGER, WARNING, CAUTION, NOTE) and their consequences.
Defines various symbols used for prerequisites, steps, lists, and cross-references.
Specifies the device's purpose and applicable surgical areas.
Covers general precautions for safe operation and electromagnetic compatibility.
Provides crucial safety guidelines for patients with pacemakers during HF surgery.
Details precautions to prevent ignition and explosions in the operating environment.
Explains correct application of the neutral electrode to prevent burns.
Identifies and describes buttons, displays, and indicators on the front panel.
Describes the monopolar sockets and neutral electrode connector on the left.
Details the bipolar sockets for instruments on the right side.
Lists and explains connectors and switches on the rear panel of the device.
Explains the meaning of various symbols found on the device and its interface.
Lists environmental requirements for device operation.
Instructions for placing and positioning the HF device correctly for operation.
Steps for connecting monopolar instruments and the neutral electrode.
Procedures for connecting bipolar instruments and foot switches.
Step-by-step guide for performing pre-service functional checks of the device.
Explains the EASY monitoring function for neutral electrode contact quality.
Details how to connect the device to the power supply and switch it on.
Explains how to read the device interface and its states.
Guide to selecting cutting or coagulation modes for specific sockets.
Instructions for adjusting the maximum output power (Watt).
How to adjust the 'Effect' setting for fine-tuning output.
Process for selecting the correct neutral electrode type and checking contact.
Details the Standard mode for cutting biological tissue with low resistance.
Explains the Forced Coag mode for fast coagulation with low tissue penetration.
Describes the Standard mode for cutting with bipolar laparoscopic instruments.
Explains the AUTOSTART function for arcless contact coagulation.
How to adjust system settings like brightness, volume, and autostart delay.
Options for selecting, deleting, sorting, and saving programs.
Explains system fault messages categorized by color (Notice, Warning, Error).
Describes fault indications for EASY monitoring in three stages: green, yellow, and red.
Provides instructions on how to safely clean and disinfect the HF device.
Details the mandatory annual safety inspection requirements for the device.
Lists detailed technical specifications, classifications, and power data for the ARC 350.
Presents performance diagrams and tables for various operating modes and settings.
Details electromagnetic compatibility guidelines and immunity requirements for the device.