Installation6
Logamax plus GB162-80 kW/100 kW - Subject to modifications resulting from technical improvements!16
z Mark both holes with the wall bracket (fig. 7) using a spirit
level.
z Install the wall bracket with 2 screws (fig. 7).
z With two people, lift the boiler by holding it by its back and
by the transport rail at its bottom and install it on the wall
bracket (fig. 5, page 14).
z The boiler can be moved sideways to get the correct
position.
z Level the boiler with the set screw and a spirit level
(fig. 8).
z Remove the protective covers from the bottom of the
boiler (fig. 9).
Fig. 7 Installing the wall bracket
A
D
C
B
Fig. 8 Aligning the boiler with the set screw
Fig. 9 Removing the covers – boiler bottom
NOTICE
Some residual water from final testing may
leak away.