TeraStation User Manual 24
Using RAID 1 mode
Change system to normal mode (page 20).1
2
3
4
5
Note:
After the RAID array is changed, the TeraStation will perfom a RAID check that will take about 5 hours per TB. File
transfers will be slower during this period. While the “RAID ARRAY x Resyncing” message is displayed on the LCD
screen, do not turn o the TeraStation. If you turn it o, the RAID check will start over.
The [Conrm Operation] screen will appear. Enter the number shown in the [Conrmation Number] eld within 6
60 seconds, and click [Apply].
Follow the instructions displayed on the screen.7
You have set up a RAID 1 array. Repeat the steps to create a second RAID 1 array with the other two drives, or refer to
page 26 to congure a hot spare with one of the remaining drives. Turn to page 43 to create a shared folder.
Click the array you want to set.
Click hard disks (Disk 1 and Disk 2, or Disk 3 and Disk 4) in RAID1.
Select [RAID 1].1
Click [Create Raid Array].2
Click [System] - [Storage] - [RAID Array] in the Web Admin interface.