21
Installation
Procedure:
→ Loosen the fastening screws countersunk in the side of the
housing (hexagon socket wrench size 2.5).
→ Rotate the Remote Sensor into the required position.
NOTE!
Too high torque when screwing in the fastening screw does
not ensure degree of protection IP65 / IP67.
▶ The fastening screw may be tightened to a maximum torque of
1.5 Nm only.
→ Tighten the fastening screws hand-tight only
(maximum torque: 1.5 Nm).
8.3 Installation of the rotating
Remote Sensor Type 8798
DANGER!
Risk of injury from high pressure in the equipment/device.
▶ Before working on equipment or device, switch off the pressure
and deaerate/drain lines.
Risk of electric shock.
▶ Before working on equipment or device, switch off the power
supply and secure to prevent reactivation.
▶ Observe applicable accident prevention and safety regulations
for electrical equipment.
WARNING!
Risk of injury from improper installation.
▶ Installation may be carried out by authorized technicians only
and with the appropriate tools.
Risk of injury from unintentional activation of the system and
an uncontrolled restart.
▶ Secure system from unintentional activation.
▶ Following assembly, ensure a controlled restart.
english
Type 8798