49
EN
12 Technical data
Softening unit Type BWT Perla one
Nominal connection width DN 32
Connection type
Nominal capacity in accordance with DIN EN 14743
min./max.
mol (m³ × °dH)
1.6 (9)/3.2 (18)
Capacity/kg of regenerative salt in accordance with
DIN EN 14743 min./max.
mol 4.2 / 6.1
m³/h See diagram of
m³/h 1.7
m³/h 1.7
Nominal pressure PN bar 10
Min./max. operating pressure bar 2 to 8
bar 1.0
Area of application according to DIN 1988-200 Residential units
People
1 – 5
2 – 12
l 6.2
Supply of regenerative, max. kg 32
Regenerative consumption per
100% regeneration, min./max. approx.
kg 0.26 / 0.76
Rinsing water consumption per
100% regeneration at 4 bar, min./max. approx.
l 32 / 40
l/h 200
Regeneration time for
100% regeneration, min./max. approx.
min. 45 / 50
Water temperature, min./max. °C 5 to 25
Ambient temperature, min./max. °C 5 to 40
Humidity Non-condensing
Power supply 230/50 – 60
Unit voltage 24
Connected load during operation, max. W 5.6
Power during regeneration, max. W 40
Fault message output, max. 24 / 0.5
Protection class IP54
kg 76
Shipping weight, approx. kg 32
Production number PNR 6-500150