©2021 CAE 905K690052 v1.0 25
Setup
Step 4: Charge the Instructor Tablet
An Instructor tablet will be provided with the Live and Advanced configurations. Remove the tablet
and tablet power adapter from the box. Connect the power adapter to the tablet. Insert the power
cord between the adapter and a power outlet.
Allow the tablet to fully charge.
Step 5: Charge the Accessories
A CAE StethoSym will be provided with the Live and Advanced configurations, and the SymDefib will
be provided with the Advanced configuration and is available as an option with the Live Configuraton.
Remove these accessories from the shipping container. Use only the provided power cords to charge
these accessories.
Note: Do not use any other power sources to charge other than the ones provided to avoid damage
to the accessories.
Charging the StethoSym
Attach the power cord and connect to a power source. The charging status of the StethoSym can be
visually detected with the following colors of the light indicator:
Charging the SymDefib
Attach the power cord to the back of the black box and connect to a power source. When the
SymDefib is turned on, the status indicator light flashes green to indicate that the unit is turned on.
Note: The SymDefib only charges while the switch is in the On position.
Light Color Power Status
Orange Unit is plugged into a power source and battery is charging.
Orange light turns off when the unit is fully charged.
Green Unit is on and fully charged.
Flashing Red Battery level is low and needs to be charged.
Blue Unit is on and receiving signal from manikin.