©2021 CAE 905K690052 v1.0 89
Care and Maintenance
Step 4: Flush and Drain the Jugular, Tibial IO and
Gastrostomy Sites
To flush and drain the Jugular, Tibial IO and Gastrostomy sites:
1. Attach IV tubing and empty IV bag to fluid drain port located at the manikin’s buttocks.
2. If non-clear distilled water was infused:
a. Remove infusing fluids from the site and attach syringe filled with
50 ml of clear distlled water.
b. Flush each site used with clear distilled water until clear water exits
from the drain port.
c. Remove syringe, discard any fluid, fill syringe with air and push air
into each site used until air exits from the drain port.
d. Remove syringe.
e. Replace cap on the jugular site, remove IO access needle from the
IO site, remove MicKey connection tube from the gastrostomy site.