M1 opening delay time
It adjusts the delay with which the fi rst leaf must start the opening manoeuvre with respect to the second leaf.
F23 M1 open delay OFF
1 to 10 seconds (Default 2)
M2 closing delay time
It adjusts the delay with which the second leaf must start the closing manoeuvre with respect to the fi rst leaf.
F24 M2 close delay OFF
1 to 25 seconds (Default 2)
Courtesy time
Set the time for which the additional light, confi gured as the courtesy light, remains on after the manoeuvre is complete.
F25 Courtesy time 60 to 180 seconds (Default 60)
M1 leaf opening and closing speed
Set the M1 travel speed (percentage of maximum speed).
F28 M1 speed 40% to 100% (Default 70%)
M2 leaf opening and closing speed
Set the M2 travel speed (percentage of maximum speed).
F29 M2 speed 40% to 100% (Default 70%)
M1 leaf opening and closing slowdown speed
Set the M1 slowdown speed during opening and closing (as a percentage of the maximum speed).
F30 M1 slowdown speed 10% to 50% (Default 40%)
M2 leaf opening and closing slowdown speed
Set the M2 slowdown speed during opening and closing (as a percentage of the maximum speed).
F31 M2 slowdown speed 10% to 50% (Default 40%)
Travel AST control
Adjust the obstruction detection sensitivity during boom travel (percent).
F34 Travel AST control 10% to 100% (Default 100%)
Slowdown AST control
Adjust the obstruction detection sensitivity during slowdown (percent).
The parameter is only used if the opening or closing slowdown point is active.
F35 Slowdown AST control 10% to 100% (Default 100%)