AF
R800
A B 1 2 3P 7 10 TS 2 C1 CX
p. 16 - Manual FA01054-EN - 01/2018 - © CAME S.p.A. -
Translation of the original instructions
Blue
White
To be able to
snap in the cards
into the dedicated
connectors, raise
the card cover.
R800 card connector (the R800 card connector is for using the
keypad selector).
⚠
For the system to work properly, before fitting any snap-in card (e.g. the AF R800), you MUST CUT OFF THE MAIN
POWER SUPPLY and remove any batteries.
OPEN-CLOSE-INVERT function (step-step) from control device
(NO contact). Alternatively, from the functions programming you
can activate the single command OPEN-STOP-CLOSE-STOP
(sequential).
STOP STOP(N.C. contact). For stopping the gate while excluding
automatic closing. To resume movement press the control button or
use another control device.
If unused, it should be deactivated during programming.
Connector for AF card (AF868 or AF43S) for remote control.
PARTIAL/PEDESTRIAN OPENING function from control device (NO
contact).
Antenna with RG58 cable for remote control.
Keypad selector.
Command and control devices