EasyManua.ls Logo

CAME OPB001CB - Safety Devices; Photocells Connection and Configuration

CAME OPB001CB
128 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10 11 E
M1 N1 ENC1
10 TS 2 C1 CX
TX
2
TX 2
10 2 TX
C
-
+
-
NC
+
-
DN10
1 2 3P 7 10 TS 2 C1 CX
p. 18 - Manual FA01054-EN - 01/2018 - © CAME S.p.A. -
Translation of the original instructions
Photocells safety connection (services test)
Reopening during closing photocells connection (NC contact) see functions
programming.
Photocells connection (NC contact), see the functions programming section.
Photocells
Configure contact CX (NC), input for safety devices such as photocell, that
are EN 12978 compliant.
During the features programming phase the CX input can be set to:
- C3 partial stop. Gate leaves stop if moving with ensuing automatic closing
(if the automatic closing feature has been inserted);
- C4 obstruction wait, leaves stop if they are moving and start moving
again once the obstruction is removed.
If unused, the CX contact should be deactivated during programming.
Signaling devices
Flashing light connection (contact rated for: 24 V AC/DC - 25 W max)
Safety devices

Related product manuals