CX/OFF 7 PWR
C1/ON PRG
1
3P
UNI 6955
3,9 x 9,5
UNI 6955
3,9 x 13
p. 26 - Manual FA01054-EN - 01/2018 - © CAME S.p.A. -
Translation of the original instructions
Fastening the transmission arm protection
Fit the protection under the operator and fasten it to the transmission arm using the screw.
Fastening the cover
Once the electrical connections and set up are done, fit the cover and fasten it using the supplied screws, then reposition
the release tab.
LEDs Description
PWR (Green)
It warns about the voltage present in the control board
PROG (Red)
It warns about the features' programming phases, the automatic closing waiting time and of any errors/
malfunctions
1 (Yellow)
It warns that contact 1-2 (NC) is open (STOP button)
3P (Yellow)
It warns that contact 2-3P (NO) is closed (partial opening button)
7 (Yellow)
It warns that contact 2-7 (NO) is closed (command button)
C1/ON (Yellow)
C1 - Signals that NC contact 2-C1 is open (photocells) / ON - Function enabled
CX/OFF (Yellow)
C - Signals that NC contact 2-C is open (photocells) / OFF - Function disabled
Alert LED
FINAL OPERATIONS