EasyManua.ls Logo

CAME OPB001CB - Functions Menu: Operational Features; Advanced Closing and Testing Functions; Button-Activated Maintained Action

CAME OPB001CB
128 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
p. 22 - Manual FA01054-EN - 01/2018 - © CAME S.p.A. -
Translation of the original instructions
Automatic closing after either partial or pedestrian opening
By default, the feature is disabled.
To enable it:
Select the DIP-switches as shown and press the PROG key on the control board. THE PRG LED stays lit
and the buzzer sounds off for 1 second.
To return to the default setting, press the PROG key again. The LED blinks and the buzzer sounds off 2
times.
⚠
The automatic closing time is permanently set to 10 seconds.
Pre-flashing (pre-flashing duration: 5 s)
By default, the feature is disabled.
To enable it:
select the DIP switches as shown and press the PROG key on the control board. The PRG LED stays on
and the buzzer sounds off for 1 second.
To return to the default setting, press PROG again. The LED blinks and the buzzer sounds off 2 times
Closing thrust
By default, the feature is disabled.
To enable it:
select the DIP switches as shown and press the PROG key on the control board. The PRG LED stays on and
the buzzer sounds off for 1 second.
To return to the default setting, press PROG again. The LED blinks and the buzzer sounds off 2 times
Saving the trimmer value
Use the trimmers to set the automatic closing time (A.C.T.), the opening and closing latching points, the
second motor's closing-delay speed, the slow-down speed (SDS) and the sensitivity (SENS.).
To save the values:
select the DIP switches as shown and press the PROG button on the control board. The PRG LED stays on
and the buzzer sounds off for 1 second.
Services test
By default, the feature is disabled.
To enable it:
Select the DIP switches as shown and press the PROG key on the control board. The LED stays on and
the buzzer sounds for 1 second.
To return to the default setting, press PROG again. The LED blinks and the buzzer sounds off 2 times
Button-activated maintained action
By default, the feature is disabled.
To enable it:
select the DIP-switches as shown and press the PROG key on the control board. The LED stays on and
the buzzer sounds for 1 second.
To return to the default setting, press PROG again. The LED blinks and the buzzer sounds off 2 times
The gate opens and closes when the button is kept pressed.
Opening button connected on 2-3P (contact NO) and closing button connected on 2-7 (contact NO)
All other control devices, even radio-based ones, are excluded.