B1 B2
10 11 ES TS 1 2 3 3P 4 5 7 CX CY CZ
R S T N
2 FA1FC1FA2FC2
10 11 ES TS 1 2 3 3P 4 5 7 CX CY CZ
UW V
XWY
E
1
E2
UW V
XWY
E
1
E2
U
Page
5 - Manual code:
FA00321-EN vers.
1 02/2017 © CAME S.p.A. - The data and information shown in this manual are to be considered subject to change at any time and without the need for any advance warning.
400 V AC (three-phase)
50/60 Hz
12 V electrolock connection
– Max. power: 15 W
Possible output of the
radio receiver’s second
channel (NO contact).
Contact rating:
1 A-24 V DC.
Power supply to accessories
Terminals for powering the
24 V AC / DC accessories-
Max. power: 30 W
ELECTRICAL CONNECTIONS
Connecting gearmotors with mechanical stops
Signalling devices
M1 - Gearmotor 400 V AC (three-
phase) delayed action on opening
M2 - Gearmotor 400 V AC (three-
phase) delayed action on closing
BLACK
BLACK / GREY
BLACK
BLACK
BLACK / GREY
BLACK
Open-gate indicator light
(Contact rating:
24V - 3W max.).
Turns on when the gate
is ajar or open.
Turns off when the gate
is closed.
Signal fl asher (contact rating:
230V - 25W max.) - Flashes during
opening and closing.
Cycle or courtesy light (contact rating: 230 V - 60 W max).
Auxiliary connection of an outdoor light, which can be positioned freely, for
better illumination in the parking/driveway area.
Cycle: it stays on from the moment the gate leaf begins to open until it is fully
closed (including automatic closing time).
Courtesy: it stays on for 5 minutes.
See function [Lamp E3] in the [FUNCTIONS] menu.