Page
10
10 - Manual code:
FA00321-EN
FA00321-EN vers.
1
1 02/2017 © CAME S.p.A. - The data and information shown in this manual are to be considered subject to change at any time and without the need for any advance warning.
Menu mapping
[LANGUAGE] Default
[Italiano] / [English] / [Français] / [Deutsch] / [Español] / [Português euro] / [Português bras]
Italiano
[FUNCTIONS] Default
[AutoClose] [Disabled] / [Turn on] [Turn on]
[Maintained Act] [Disabled] / [Turn on] / [When close] [Disabled]
[Obstacle Det] [Disabled] / [Turn on] [Disabled]
[Safety Test] [Disabled] / [CX] / [CY] / [CZ] / [CX+CY] / [CX+CZ] / [CY+CZ] / [CX+CY+CZ] [Disabled]
[Preflashing] [Disabled] / [Turn on] [Disabled]
[Ram hit funct] [Disabled] / [Turn on] [Disabled]
[Total Stop] [Disabled] / [Turn on] [Turn on]
[CX input] [Disabled] / [C1] / [C2] / [C2] / [C4] / [C7] / [C8] [C1]
[ CYInput] [Disabled] / [C1] / [C2] / [C2] / [C4] / [C7] / [C8] [C3]
[ CZInput ] [Disabled] / [C1] / [C2] / [C2] / [C4] / [C7] / [C8] [Disabled]
[Cl. Thrust] [Disabled] / [Turn on] [Disabled]
[Lock ] [Disabled] / [Turn on] [Disabled]
[Config] [Endstop] / [Slow run*] / [Fcap-RallCh*] / [ENCODER*] / [Time of Run*] [Endstop]
[Endstop] [NC / NO*] [NC]
[Cmd 2-7] [Open-Close] / [Op.-Stop-Cl] [Open-Close]
[Cmd 2-3P] [Partial] / [Pedestrian] [Pedestrian]
[Lamp E3] [Courtesy] / [Cycle] [Cycle]
[Output B1-B2] [Monostable] / [Bistable] [Bistable]
[No. Motors] [M1+M2] / [M2]; [M1+M2]
[CRP Address] [1]
[32]
[CRP baudrate] [1200] / [2400] / [4800] / [9600] / [19200] / [38400] / [57600] / [115200] [38400]
* Although the software includes the following functions, they should not be used.
[TIMING ADJ] Default
[A.C.T.] [0 s]
⇨
[300 s] [10 s]
[
Pedestrian ACT
] [0 s]
⇨
[300 s] [10 s]
[Cycle Time] [10 s]
⇨
[150 s] [90 s]
[Op. Delay M1] [0 s]
⇨
[10 s] [2 s]
[Cl. Delay M2] [0 s]
[60 s] [2 s]
[Preflashing T.] [1 s]
⇨
[60 s] [5 s]
[Lock time] [1 s]
⇨
[5 s] [2 s]
[Ram hit time] [1 s]
[10 s] [1 s]
[Ped. opening] [5 s]
[60 s] [10 s]
[USERS] Default
[Add User] (250max)
[Mod. name]
[Mod. Code]
[Related Func] [2-7] / [Open] / [B1-B2] / [2-3P] / [];
[Remove Usr]
[Delete all Usr] [Confirm? (no)] / [Confirm? (yes)]
[Backup data] [Confirm? (no)] / [Confirm? (yes)]
[Restore backup] [Confirm? (no)] / [Confirm? (yes)]
[INFO]
[Version] / [No. of runs] / [Standby Msg] / [System Reset]
[TEST MOT]
[<=M1 M2=>]
Key for the abbreviations used in the menu items
[Ped.opening
]
Partial opening
[Maintained Act
]
Maintained Act
[AutoClose
]
Automatic closing
[Config
]
Configuration
[CRP
]
Came Remote Protocol
[Related Func
]
Related Function
[Mod. Code
]
Modify code
[Standby Msg
]
Standby message
[No. Motors
]
Number of motors
[Obstacle Det
]
Obstacle Detection
[Remove Usr
]
Remove User
[Op. Delay M1
]
M1 opening delay
[Cl. Delay M2
]
M2 closure delay
[Cl. Thrust
]
Closing thrust
[Ram hit time
]
Ram hit time
[Preflashing T
]
Preflashing time
[Lock time
]
Lock time
[A.C.T.
]
Automatic closing time
[
Pedestrian ACT]
Pedestrian automatic closing time

Related product manuals