11 - Manual code:
FA00321-EN
FA00321-EN vers.
1
1 02/2017 © CAME S.p.A. - The data and information shown in this manual are to be considered subject to change at any time and without the need for any advance warning.
Language menu
[LANGUAGE]
[Italiano] / [English] / [Français] / [Deutsch] / [Español] / [Português euro] / [Português bras]
Select the language from the available options
[FUNCTIONS]
[AutoClose] [Disabled] / [Turn on]
The waiting time before the gate closes automatically starts when the endstop point is reached during opening. The time can be set to between
0 s and 300 s. The gate is not closed automatically where the safety devices are triggered by an obstacle, after a total stop or where there is
no power.
[Maintained Act] [Disabled] / [Turn on] / [When close]
The leaves open and close by pressing and holding a button. Opening button on contact 2-3; closing button on contact 2-4. All other command
devices, including radio-controlled devices, are excluded.
[Obstacle Det] [Disabled] / [Turn on]
With the gate leaves open or closed or after a total stop, if the safety devices (photocells or sensitive edges) detect an obstacle the gate does
not operate automatically.
[Safety Test] [Disabled] / [CX] / [CY] / [CZ] / [CX+CY] / [CX+CZ] / [CY+CZ] / [CX+CY+CZ]
After each opening and closing command, the board checks that the photocells are working correctly.
[Prefl ashing] [Disabled] / [Turn on]
After an opening or closing command is given, the fl ashing light connected to E1-E2 fl ashes before the gate begins to move.
To adjust the time, see
[Preflashing T]
in the
[TIMING ADJ]
menu.
[Ram hit funct] [Disabled] / [Turn on]
Before an opening or closing manoeuvre, the leaves push on the mechanical endstop to help release the electrolock. To set the thrust time,
select
[Ram hit time]
in the
[TIMING ADJ]
menu.
[Total Stop] [Disabled] / [Turn on]
NC Input – Stop gate while excluding the automatic closing cycle; to resume movement, use the command device. The safety device should
be inserted in 1-2.
[CX Input]
[Disabled] / [C1] / [C2] / [C3] / [C4] / [C7] / [C8]
NC Input – Possible associations: C1 = re-open during closing for photocells, C2 = re-close during opening for photocells, C3 = partial stop,
C4 = stand-by Obstacle, C7 = re-open while closing for sensitive edges, C8 = re-close while opening for sensitive edges.
[CY Input]
[Disabled] / [C1] / [C2] / [C3] / [C4] / [C7] / [C8]
NC Input – Possible associations: C1 = re-open during closing for photocells, C2 = re-close during opening for photocells, C3 = partial stop,
C4 = stand-by Obstacle, C7 = re-open while closing for sensitive edges, C8 = re-close while opening for sensitive edges.
[CZ Input]
[Disabled] / [C1] / [C2] / [C3] / [C4] / [C7] / [C8]
NC Input – Possible associations: C1 = re-open during closing for photocells, C2 = re-close during opening for photocells, C3 = partial stop,
C4 = stand-by Obstacle, C7 = re-open while closing for sensitive edges, C8 = re-close while opening for sensitive edges.
[Cl. Thrust] [Disabled] / [Turn on]
At the endstop during closing, a fi nal closing-thrust of the doors is performed automatically for a few seconds.
[Lock] [Disabled] / [Turn on]
Electrolock to lock the gate leaves. Required for gate leaves longer than 2.50 m.
[Confi g] [Endstop] / [Slow run] / [Fcap-RallCh] / [ENCODER] / [Time of Run]
Configure decelerations when opening or closing.
Warning! Although the software includes the functions
[Slow run], [Fcap-RallCh], [ENCODER] and [
Time of Run], they should not be used.
Select the function [Endstop].
Functions menu
IMPORTANT! Start programming by setting the first functions [No. Motors] and [Total Stop].