Table 9-1: CR6 terminal commands
Command Description Use
J
Download file dump Sends text of current program including comments.
K
Minion status Campbell Scientific engineering tool
L
Peripheral bus read Campbell Scientific engineering tool
M
Memory check Lists memory-test results
N
File system information Lists files in CR6 memory.
O
Data table sizes Lists technical data concerning data-table sizes.
P
Serial talk through
Issue commands from keyboard that are passed
through the logger serial port to the connected
device. Similar in concept to SDI12 Talk Through. No
timeout when connected via PakBus.
REBOOT
Program recompile
Typing REBOOT rapidly will recompile the CR6
program immediately after the last letter, "T", is
entered. Table memory is retained. NOTE: When
typing REBOOT, characters are not echoed (printed
on terminal screen).
SDI12
SDI12 talk through
Issue commands from keyboard that are passed
through the CR6 SDI-12 port to the connected device.
Similar in concept to Serial Talk Through. See also
SDI-12 transparent mode (p. 140)
T
Unused
U
Data recovery
Provides the means by which data lost when a new
program is loaded may be recovered. Contact
Campbell Scientific support.
V
Low level memory dump Campbell Scientific engineering tool
W
Comms Watch (Sniff)
Enables monitoring of CR6 communication traffic.
No timeout when connected via PakBus.
X
Peripheral bus module
identify
Campbell Scientific engineering tool