OPERATION USING ID(S), Cont.
Adding to the Accumulator for a Non-Active ID.
NOTE: The following steps change the Non-Actve ID to the
Active ID to ADD to the Accumulator.
1. With scale in the Weight mode (the Count display is
blank), press the ID key.
2. The ID annunciator will flash, the weight display will
show id=id=, and the count display will show the current
active ID.
3. Using the numeric keypad, key-in the desired
identification number and press the ENTER key.
4. The ID annunciator will stop flashing and stay on, and
the scale will return to the Weight mode.
5. Press the SAMPLE key, then add or remove the number
of pieces indicated on the display.
6. Press the COUNT or ENTER key, add or remove the
pieces to be counted and read the total count.
7. With the display showing the current count (COUNT
annunciator ON) press the ++ key to add to (or the - key to
subtract from) the displayed count of the accumulator.
The ACCUM annunciator will flash to show that the
adjustment to the accumulator has taken place and will
continue to flash until all pieces are removed from
platform and the display returns to zero in preparation for
the next counting operation.
8. Press the ENTER key to return to the Weight mode.
NOTE: Additional accumulator adjustments can not take place until the next
counting operation has been completed.
23
id= 1524
ID
Add 5
0.000
SAMPLE
II0
COUNT
ACCUM
II0
0.000
lb
1 2 3 4 5
6 7 8 9 0
ID
0.000