EasyManua.ls Logo

Cardinal 2240 - OPERATIONAL SETUP, Cont.; EUROPEAN DATE; MANUAL COUNT OVERRIDE; PRINTER OUTPUT

Cardinal 2240
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CALIBRATION and SETUP, Cont.
OPERATIONAL SETUP, Cont.
SCALE 2 (Optional remote scale)
The display will show scal2scal2, the prompt to enable or disable the optional remote scale and
display the current setting. To change the setting, press the YES/1 key to enable or the NO/0
key to disable, then press the ENTER key to save the setting and proceed to the next prompt.
NOTE: The REMOTE scale cannot be used until it has been calibrated (refer to the
Calibration Procedure - Remote Scale section).
AUTO LOCAL-TO-REMOTE SWITCH
The display will show a suta sut, the prompt to enable or disable the Auto Switching from the
sample scale to the bulk scale for counting operations and display the current setting. This
feature, when enabled will use the integral (local) scale for the sample then automatically
switch to the bulk (remote) scale for counting with the acceptance of the sample. To change
the setting, press the YES/1 key to enable or the NO/0 key to disable, then press the ENTER
key to save the setting and proceed to the next prompt.
AUTO RECALL OF LAST AVERAGE PIECE WEIGHT
The display will show a RcLa RcL, the prompt to enable or disable the Auto Recall of the Average
Piece Weight on power up and display the current setting. This feature, when enabled will
automatically recall the last average piece weight after turning the scale on. To change the
setting, press the YES/1 key to enable or the NO/0 key to disable, then press the ENTER key
to save the setting and proceed to the next prompt.
AUTO ACCUMULATION
The display will show a acca acc , the prompt to enable or disable Auto Accumulation of counts
and display the current setting. This feature, when enabled will automatically accumulate the
counts after a counting operation. If disabled, the operator must press the ACCUM key to
accunulated the counts. To change the setting, press the YES/1 key to enable or the NO/0
key to disable, then press the ENTER key to save the setting and proceed to the next prompt.
BEEPER
The display will show beeprbeepr, the prompt to enable or disable the internal beeper and display
the current setting. This feature, when enabled will sound the beeper each time a key is
pressed and when an error occurs. If disabled, the beeper will only sound when an error
occurs. To change the setting, press the YES/1 key to enable or the NO/0 key to disable,
then press the ENTER key to save the setting and proceed to the next prompt.
STORE ID
The display will show str idstr id, the prompt to enable or disable the Identification Number (ID)
feature and display the current setting. To change the setting, press the YES/1 key to enable
or the NO/0 key to disable, then press the ENTER key to save the setting and proceed to the
next prompt.
12 HOUR CLOCK
The display will show 12 hr12 hr, the prompt to enable or disable the 12 Hour clock feature and
display the current setting. This feature, when enabled will select the 12 hour time format for
printing the time on tickets. Note that an "a" for am or an "p" for pm will not print on the ticket.
If disabled, the time will be in the 24 hour (military) time format. To change the setting, press
the YES/1 key to enable or the NO/0 key to disable, then press the ENTER key to save the
setting and proceed to the next prompt.
NOTE: The 12 Hour Clock feature only affects how the time is printed on tickets. The time is
set using the 24 hour (military) format whether the 12 Hour clock feature is enable or
disabled.
26