Loading...
10
F=
br=
If the setting displayed is acceptable, press the ENTER key to save it, otherwise, enter 0,1, 2, or 3
for the new setting and press the ENTER key. If you selected 3 (Custom Filtering) the 708 will ask
for two additional parameters:
Filter Level
press the ENTER key to show the current setting for the
filter level. The filter level is a number from 1 to 16 that
corresponds to the level of filtering with 16 being the
greatest filtering and 1 the least. To accept the value
displayed, press the ENTER key, otherwise, use the
numeric keys to enter a new value and press the ENTER
key to save it. The 708 will then ask for a second
parameter:
Break Range
press the ENTER key to show the current setting for the
break range. The break range is a number from 1 to 64
that corresponds to the number of division change to
break out of the filtering. Press the ENTER key to keep
the displayed value or use the numeric keys to enter a
new value and press the ENTER key to save the new
setting.
MOTION RANGE
press the ENTER key to view the current setting for the
range of motion detection. If the displayed value is
acceptable, press the ENTER key to save it. Otherwise,
enter the new range by entering the number of divisions
of change permitted before indicating unstable, then
press the ENTER key to save the new setting. Ranges
of 1 to 9 divisions are acceptable.
press the ENTER key to show the current setting for the
sample rate. The value displayed is the sample rate in
samples per second. Press the ENTER key to save the
displayed value or use the numeric keys to enter a new
value (1 to 12) and press the ENTER key to save it.
AUTO SHUTOFF
press the ENTER key to show the current status for this
feature. A number other than 0 indicates that the auto
shutoff feature is enabled and the displayed number
corresponds to the number of minutes of stable weight
display before the 708 is turned off automatically. A 0
indicates that the feature has been turned off. This
feature is handy for turning the scale off when it is not in
use. Press the ENTER key to save the current setting or
enter a new value (0 to 9) and press the ENTER key to
store the new setting.
SLEEP MODE
press the ENTER key to show the status of this feature.
If a number other than 0 is shown, this feature is
selected and the number shown corresponds to the
number of minutes of a stable zero weight reading
before the indicator enters the power-conserving sleep
mode. If the current setting is to remain unchanged,
press the ENTER key, else, use the numeric keys to
enter a new value (0 to 9) and press the ENTER key.
Note that entry of a 0 disables this feature.